LASER TECHNOLOGIES

CARBOMAX

Two Wavelengths. One Professional Platform.

A professional Q-switched Nd:YAG laser platform combining 1064 nm and 532 nm wavelengths with nanosecond pulse delivery and interchangeable focus heads.

Product Introduction

A professional Q-switched Nd:YAG laser system developed for medical-aesthetic clinics and specialised treatment environments. CARBOMAX combines 1064 nm and 532 nm wavelengths with nanosecond pulse delivery, wavelength-specific focus heads and a carbon peeling applicator. Its touchscreen interface brings function selection, energy control, frequency management and shot-count information into one mobile platform.

PROFESSIONAL PIGMENT AND TATTOO LASER PLATFORM

Dual-wavelength control for specialised professional workflows

CARBOMAX provides two Q-switched Nd:YAG wavelengths within a single professional platform. The 1064 nm and 532 nm outputs allow trained operators to select a wavelength, applicator and parameter approach according to the intended treatment, pigment characteristics and approved clinical protocol.

The system pairs nanosecond pulse delivery with adjustable energy and frequency, a visible aiming beam, real-time system information and foot-switch activation. Dedicated heads support wavelength-specific operation, while the carbon peeling head extends the platform to carbon-assisted facial protocols.

Concluding Statement

A focused professional platform for practices that require dual-wavelength Nd:YAG capability, structured parameter control and several applicator options.

Key Value Pillars

Two wavelengths within one platform

The 1064 nm and 532 nm configuration gives the operator two wavelength options for professionally assessed pigment and tattoo treatment workflows.
Supporting evidence: 1064 nm and 532 nm output documented in the catalog and user manual.
Professional relevance: Allows wavelength selection to form part of a considered professional protocol.

Nanosecond pulse delivery

CARBOMAX delivers 4.5 ns pulses at 1064 nm and 4 ns pulses at 532 nm, with an adjustable energy range of 100 to 2000 mJ.
Professional relevance: Supports controlled parameter selection according to wavelength, target characteristics and professional assessment.

Dedicated heads for different workflows

The handpiece accepts 1064 nm and 532 nm focus heads together with a dedicated carbon peeling head.
Professional relevance: Keeps wavelength selection and applicator choice visible within the working sequence.

Interface organised around treatment functions

The colour touchscreen provides treatment-function selection, energy and frequency adjustment, system temperature, water-flow information and shot counting.
Professional relevance: Brings the principal operating information together in one control environment.

LASER TECHNOLOGIES

Technologies

01

Q-Switched Nd:YAG Laser Platform

Operating principle: The system delivers short, high-energy laser pulses that interact selectively with targeted pigment. The professional protocol must account for wavelength, pigment characteristics, treatment area, skin characteristics and the intended endpoint.

Confirmed parameters: 1064 nm and 532 nm wavelengths, 100 to 2000 mJ energy range and 1 to 10 Hz frequency range with energy-dependent limits.

Professional value: Provides dual-wavelength capability within one mobile professional system.

Qualification: Use by medical professionals or appropriately trained operators in accordance with approved instructions, assessment and local requirements.

1064 nm Wavelength

Role within the system: The 1064 nm output forms the longer-wavelength operating option and is paired with the 1064 nm focus head.

Pulse duration: 4.5 ns

Professional application scope: Professionally assessed treatment of selected darker tattoo inks and deeper pigment targets where the approved protocol supports 1064 nm operation.

532 nm Wavelength

Role within the system: The 532 nm output forms the shorter-wavelength operating option and is paired with the 532 nm focus head.

Pulse duration: 4 ns

Professional application scope: Professionally assessed treatment of selected superficial pigment targets and appropriate tattoo colours where the approved protocol supports 532 nm operation.

02

Carbon Assisted Treatment Mode

Operating principle: The carbon peeling head supports protocols that use an applied carbon medium with 1064 nm laser delivery.

Professional value: Adds a distinct carbon-assisted facial workflow to the platform.

Limitation: No whitening, pore-reduction, collagen-stimulation, rejuvenation or outcome guarantee is made in this website version.

Technologies

Professional Applications

CARBOMAX is intended for professional Q-switched Nd:YAG workflows following individual assessment by a medical professional or appropriately trained operator. Wavelength, energy, frequency, spot size and treatment endpoint must follow the approved instructions and local professional requirements.
01

Professional tattoo pigment workflows

Supports professionally assessed treatment planning for selected body and cosmetic tattoo pigments using the wavelength and focus head appropriate to the target.

02

Professional pigmentation workflows

Supports professional assessment and treatment planning for selected epidermal and dermal pigment concerns where Nd:YAG laser treatment is appropriate.

03

Carbon assisted facial workflows

The dedicated carbon peeling head supports carbon-assisted facial protocols performed by trained operators within the approved operating framework.

Professional Use Limitation

Treatment suitability and response vary by pigment, skin characteristics, previous treatment history and individual factors. CARBOMAX does not guarantee removal, clearance, comfort, absence of downtime or a specific number of sessions.

Components

Applications and Components

Component Function and confirmed parameters Configuration and care
Main laser handpiece Hand tool output with changeable wavelength and carbon-treatment heads. Included. Clean and disinfect according to the approved instructions after use.
1064 nm focus head Longer-wavelength applicator for approved 1064 nm protocols. Included in the documented source configuration.
532 nm focus head Shorter-wavelength applicator for approved 532 nm protocols. Included in the documented source configuration.
Carbon peeling head Applicator for carbon-assisted 1064 nm protocols. Included in the documented source configuration.
Foot switch Controls laser emission after the system enters the working state. Included in the documented accessory list.
Protective glasses and patient eyeshade Laser eye protection for the operator and patient. Mandatory use according to the approved instructions and local laser-safety requirements.
Remote interlock connector Supports room-level laser safety integration. Included in the documented accessory list.
Water filling accessories and CPC parts Support filling and operation of the water-circulation system. Use purified or distilled water only, following the operating instructions.
INTERFACE AND CONTROL

Clear access to functions, parameters and system status

The 10.4 inch colour touchscreen organises treatment-function selection and parameter management within one interface. The documented menu includes professional modes for tattoo, pigmentation and carbon-assisted workflows. Operators can review energy, frequency, temperature and shot-count information before and during operation.

  • Energy adjustment from 100 to 2000 mJ, subject to wavelength and frequency limits.
  • Frequency adjustment from 1 to 10 Hz, with reduced maximum frequency at higher energy settings.
  • Current and cumulative shot-count display.
  • Real-time system temperature and water-flow information.
  • Visible 650 nm aiming beam control.
  • Standby and working-state control with foot-switch activation.
Presets and displayed functions support trained operators. They do not replace professional assessment, approved instructions or local safety requirements.

A structured path from preparation to controlled operation

CARBOMAX combines a mobile floor-standing design with organised handpiece support, foot control and a water-cooled laser architecture. The operating sequence moves from system checks and patient assessment to head selection, parameter review, standby and controlled laser activation.

  • Professional installation and system preparation, including the purified or distilled water circuit.
  • Selection of the appropriate wavelength head or carbon peeling head.
  • Energy, frequency and aiming-beam review before laser activation.
  • Foot-switch controlled output after the system enters the working state.
  • Cleaning and disinfection of the treatment head after each use.
  • Periodic water replacement and maintenance according to the approved documentation.
DESIGN PHILOSOPHY

Designed around the operator and the treatment room

The floor-standing system combines an angled touchscreen, dedicated handpiece holder, emergency-stop control and mobile casters within a compact vertical form. Rear and internal service elements group the water tank, cooling architecture, power module and safety connections within the main unit.

  • Angled 10.4 inch touchscreen for direct operator access.
  • Dedicated handpiece holder and support structure.
  • Emergency-stop button and key-controlled system access.
  • Four casters for positioning within a suitable treatment room.
  • Integrated water tank, pump and air-plus-water cooling architecture.
Professional Experience

Focused control throughout the treatment workflow

CARBOMAX keeps the principal operating decisions visible. The operator selects the intended function, fits the corresponding head, reviews energy and frequency, confirms the aiming beam and monitors temperature, water flow and shot count. The foot switch then provides controlled activation while the handpiece remains the primary treatment interface.

Training and Integration

Professional preparation for responsible system use

OMAX can support CARBOMAX integration through installation guidance, product introduction and operator familiarisation. Training should cover laser safety, wavelength and applicator selection, interface navigation, parameter principles, patient assessment, cleaning and routine maintenance.

Support Availability

CARBOMAX is intended for medical professionals or appropriately trained operators. Local qualification, registration and laser-safety requirements apply.

Availability Disclaimer

Training format, language, duration and certification arrangements may vary by market and authorised distribution partner.

Technical Support

Professional support for installation and ongoing operation

OMAX provides access to installation guidance, technical support, maintenance and servicing options for CARBOMAX, together with spare-parts support under the applicable commercial terms. The support package depends on the supplied configuration and local market arrangements.

  • Installation and initial system checks.
  • Operator onboarding and technical familiarisation.
  • Troubleshooting and maintenance guidance.
  • Preventive maintenance and servicing arrangements.
  • Spare-parts and component support.

Support Availability

CARBOMAX is intended for medical professionals or appropriately trained operators. Local qualification, registration and laser-safety requirements apply.

System

Parameter Published specification
Product OMAX CARBOMAX
System type Professional Q-switched Nd:YAG laser system
Construction Mobile floor-standing platform
Main screen 10.4 inch colour touchscreen
Rated system power 600 W
Cooling architecture Integrated water circulation with air cooling
Water tank capacity 5 litres

Laser Output

Parameter Published specification
Laser wavelengths 1064 nm and 532 nm
Pulse duration at 1064 nm 4.5 ns
Pulse duration at 532 nm 4 ns
Energy range 100 to 2000 mJ
Frequency range 1 to 10 Hz, subject to energy-dependent limits
Frequency by energy 100 to 1000 mJ at 1 to 10 Hz; 1100 to 1500 mJ at 1 to 9 Hz; 1600 to 2000 mJ at 1 to 8 Hz
Aiming beam 650 nm red light
Spot size Approximately 1 to 5 mm, adjusted through working distance according to the approved protocol

Electrical and Operating Environment

Parameter Published specification
EU working voltage AC 220 V ±10 percent, 50 Hz
Recommended room temperature Approximately 25 °C
Relative humidity 80 percent or below
Atmospheric pressure 860 to 1060 hPa
Transport and storage temperature -20 °C to 60 °C
Exact machine dimensions, net weight and package dimensions are intentionally withheld because the supplied catalog and user manual conflict. Final specifications and supplied components remain subject to the confirmed commercial documentation.

Documentation & Downloads

Documentation & Downloads

Document Availability
Product Brochure To be developed from the approved website content.
Technical Specifications Available on request after confirmation of the supplied configuration.
User Manual Professional or post-purchase access.
Training Materials Provided during onboarding and professional training.
Application Guidance Professional or post-purchase access, subject to approved use and operator requirements.
Cleaning and Maintenance Guidance Provided during onboarding and post-purchase support.
Certificates and Declarations Available to qualified professional purchasers on request where applicable to the market and exact product configuration.

Evidence and Compliance

Professional operation within an approved framework

CARBOMAX is intended for use by medical professionals or appropriately trained operators within professional medical-aesthetic or aesthetic environments. Operation must follow the approved instructions, applicable European Union and local requirements, individual suitability assessment and appropriate laser-safety measures, including the specified eye protection and room controls.

Regulatory status, documentation, operator requirements and product availability may vary by European Union market and supplied configuration. Contact OMAX or the authorised distribution partner for the documentation applicable to the exact product supplied.

Related Systems

CEMAX

CEMAX

A professional electromagnetic platform combining an integrated treatment chair with two external body applicators for structured pelvic floor and body-conditioning workflows.

DERMOMAX RF

DERMOMAX RF

A professional 2 MHz RF system combining vacuum-assisted microneedling, non-needle fractional RF, monopolar RF and cooling.

PREMIOLASE PRO

PREMIOLASE PRO

Eine professionelle Diodenlaserplattform mit vier Wellenlängen, einem Behandlungshandstück mit 1800 W, austauschbaren Behandlungsköpfen und integrierter Kontaktkühlung.

Evaluate CARBOMAX for your practice

Discuss your intended professional applications, operator requirements, preferred configuration and support needs with OMAX. We will help you review whether CARBOMAX fits your treatment environment and arrange a closer product demonstration.
Diese Website ist auf wpml.org als Entwicklungsseite registriert. Wechseln Sie zu einem Produktions-Website-Schlüssel, um remove this banner.